Filter Results By:

Products

Applications

Manufacturers

Showing results: 1876 - 1890 of 2617 items found.

  • Pressure Sensors

    Sencera Co.

    Pressure sensors have particular utility for monitoring the pressure in a fluid network. As compared with flow sensors, pressure sensors often require less cost to achieve a similar result. Pressure sensors are often fabricated using thin membranes that flex under pressure.Some pressure sensors function in a binary manner, i.e., when pressure is applied to a pressure sensor, the sensor acts to complete or break an electical circuit. Some speed cameras use them.

  • Relays

    PO3000 - Mors Smitt Group

    Various contact materials are available to meet particular circuit conditions and operating environments, including pure silver, palladium and platinum, and silver-nickel and gold-nickel alloys. PO3000 relays can be configured to operate at voltages from 5V to 250V with operate delays up to 100mS and release delays up to 500mS. Mors Smitt also offer a comprehensive service/repair, re-test and re-certification service for PO3000 type relays where this can provide an economical alternative to purchasing new relays.

  • Static & Lighting Chokes

    LBA Group, Inc

    Lighting chokes are used to pass tower lighting voltages across the base insulator of a series-fed tower without appreciably altering the tower impedance. LBA TC-300 general purpose tower lighting chokes are provided for three wire 110/220 VAC circuits. Maximum current is 25 amps. These chokes are rated for peak base voltages to 10,000 volts, and present a typical reactance of +j5000 ohms at 530 kHz. Bypass capacitors are provided on each winding.

  • Snap / Toggle Switches

    Panasonic Industrial Devices Sales Company of America

    A Snap/Toggle Switch is an Operational Switch that is manually operated and can be used to select between ON-OFF states. Snap/Toggle switches are used when an engineer would like a manual circuit control that has simple and reliable operation. Panasonic Snap/Toggle Switches are capable of high capacity switching in a small package size. Panasonic has a variety of Sealed Types for use in different environments with both Rocker and Push-button Actuators available. The terminals are constructed for easy implementation..

  • Dynamic Micro Ohm Meter

    PRIME 200 - EUROSMC, S.A.

    It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 200 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.

  • Dynamic Micro Ohm Meter

    PRIME 600 - EUROSMC, S.A.

    It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 600 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.

  • 4 Discrete/Switch I/O Channels (±100 V, 3 A/Ch.)

    DT3 - North Atlantic Industries

    The DT3 module (the enhanced version) feature 4 independent, high current, isolated, programmable channels that can be used for input voltage measurements (±100 V), or as a bi-directional current switch (up to 3 A per channel). When programmed as a switch with the switch closed, both the current through the switch and the voltage across the switch can be monitored. These modules include diode clamping on each channel. Clamping is useful for inductive loads, such as relays and short circuit protection.

  • British Rail Relays

    Mors Smitt Group

    Mors Smitt manufacture the full range of British Rail equivalent relays including AC & DC coils, instantaneous, gold contacts, safety critical, push to test relay button, timer/time delay, and flashing. These relays can be found throughout Rolling Stock vehicles including locomotives, diesel multiple units (DMUs), electric multiple units (EMUs) and light rail trams. Applications include circuits involved with lighting, doors, brakes and alarms.

  • Accelerated Stress Test Chamber

    Cincinnati Sub-Zero Products

    CSZ's accelerated stress test chambers combine mechanical refrigeration; LN2 cooling and high velocity air flow for fast product temperature change rates. Chambers are typically designed with a change rate up to 30C (54F) per minute based upon the part temperature. Common uses are production stress testing circuit boards, electronic drives, assemblies, etc. Design allows the user to quickly control and change the temperature of the product.

  • Energy Monitoring Devices

    Omron Industrial Automation

    *Over 20 years of history in Power Monitoring Technology.*Compact with multi-circuit capabilities (up to 4 circuits connected to one unit).*Solve design, installation, wiring, and commissioning issues with only one model.*IEC 62053-22 accuracy class 0.5S*Push-in plus technology for easy wiring*Automatic LED and acoustic alarm in case of incorrect wiring*Large, easy-to-read, white LCD.*DIN rail mounting*Bi-directional power measurement

  • ESD Testing & Latch-Up Testing Services

    Evans Analytical Group®

    EAG is an industry leader in ESD testing (Electrostatic Discharge) and Latch up testing. Our highly experienced engineering team use their industry leading knowledge and years or real world experience of the latest semiconductor technologies, circuit design, and device physics to optimize our customer's ESD and latch-up results. Human Body Model (HBM) and Machine Model (MM), Charged Device Model (CDM), Latch-up, Transmission Line Pulse (TLP).

  • Noise Sensor

    CRY2100 Series - Hangzhou JiGao Electroacoustical Science and Technology Co.,Ltd

    CRY2110 / 2112 noise sensor is a new type of noise testing equipment for industrial applications. Product performance implements IEC61672-1 / 2 standard and GB / T3785-1 / 2 standard. CRY2110 / 2112 noise sensors are small in size and equipped with precision measurement microphones to ensure good temperature and humidity characteristics. The sensor's integrated signal conditioning, amplification, sampling, and calculation circuits can provide a dynamic range of 110dB and measure environmental noise as low as 25dBA.

  • Single-Inline Package (SIP) Relays

    Series LS - Teledyne Defense Electronics Relays & Coax Switch

    Series LS single-inline package (SIP) relays are designed for mounting on printed circuit boards. LS relays facilitate heat sinking by providing an metallic interface surface. The relays use a direct-bonded copper substrate for thermal efficiency, thermal stress performance and long-life expectancy. Optional heat sinks are available.​Available options include:LS24D16C 50A, 90-280Vac, 600Vpeak Load; 4-20mA ControlSHP24N50R 50A, 100-280Vac, 600Vpeak Load; 8-30​Vdc Control

  • Series Voltage References

    Analog Devices Inc.

    Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.

  • Cable Identification & Phasing

    VCi-3™ - ndb Technologies Inc.

    The VCi-3™ system is designed for cable and phase identification, mainly for instal­lation or maintenance purposes on three-phase electrical networks during power shutdowns.The transmitter module injects a low current on the cable conductors by direct con­tact or magnetic clamps methods. A voice message is recorded by the user and will be transmitted along with digital signals. Groundings stay connected at both ends of the three-phase circuit during the test. The detector module is used at the other end of the cable system.

Get Help